Probleemoplossing - Blodgett KLS-100E

Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.

9 van 9

Overige problemen 6

Probleem Oorzaak Oplossing

Installatie & Opstelling 1

Probleem Oorzaak Oplossing
Heating elements do not turn on Kettle is not in vertical position (KLT-E series only) or control circuit is interrupted Ensure kettle is in vertical position so circuit is completed through the tilt interlock switch

Waterproblemen 2

Probleem Oorzaak Oplossing
Low Water light turns on and heating element cuts off Water level in kettle jacket is inadequate Check and refill the kettle jacket water reservoir to adequate level to prevent low water cut-off device activation
Vacuum pressure gauge reading is abnormal Air is present in the steam jacket system Open the bleed vent one full turn for 10 seconds with the kettle reservoir at pressure above 0 PSI to eliminate air from the system