Blodgett KLS-100E
Waterkoker · 9 Probleemoplossingen
Probleemoplossing - Blodgett KLS-100E
Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.
Overige problemen 6
| Probleem | Oorzaak | Oplossing |
|---|---|---|
Installatie & Opstelling 1
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Heating elements do not turn on | Kettle is not in vertical position (KLT-E series only) or control circuit is interrupted | Ensure kettle is in vertical position so circuit is completed through the tilt interlock switch |
Waterproblemen 2
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Low Water light turns on and heating element cuts off | Water level in kettle jacket is inadequate | Check and refill the kettle jacket water reservoir to adequate level to prevent low water cut-off device activation |
| Vacuum pressure gauge reading is abnormal | Air is present in the steam jacket system | Open the bleed vent one full turn for 10 seconds with the kettle reservoir at pressure above 0 PSI to eliminate air from the system |