Probleemoplossing - Honeywell RTH7500D

Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.

22 van 22

Overige problemen 9

Probleem Oorzaak Oplossing

Compressor 1

Probleem Oorzaak Oplossing
'Wait' shows in the display Compressor minimum-off timer is active Wait up to five minutes for the cooling or heating system to turn on

Installatie & Opstelling 6

Probleem Oorzaak Oplossing
Cannot set System setting to Cool Installer Setup Number 0170 setting does not match installed system type Check Installer Setup Number 0170, Heating and/or Cooling System Type; make sure the setting matches the installed heating and/or cooling system
Fan does not turn on in a call for heat (electric furnaces only) Installer Setup Number 0180 setting not configured for Electric Heat Check Installer Setup Number 0180, Fan Control in Heating, and make sure it is set to Electric Heat
Heat pump puts out cool air in the heat mode and warm air in the cool mode (heat pumps only) Installer Setup Number 0190 changeover valve setting does not match installed heat pump Check Installer Setup Number 0190, Heat Pump Changeover Valve, and make sure the setting matches the changeover required by the installed heat pump
Zowel het verwarmings- als het koelsysteem werken tegelijkertijd Onmatch in systeemtypeinstellingen of bekabelingsprobleem Controleer het installatiesetupnummer 0170, verwarmings- en/of koelsysteemtype, en zorg ervoor dat de instelling overeenkomt met het geïnstalleerde systeem. Controleer of de blote delen van de draden elkaar niet raken
Verwarmingssysteem werkt in koelmodus Installatiesetupnummer 0170 instelling komt niet overeen met het geïnstalleerde systeemtype Controleer het installatiesetupnummer 0170, verwarmings- en/of koelsysteemtype, en zorg ervoor dat de instelling overeenkomt met het geïnstalleerde verwarmings- en/of koelsysteem

Stroomvoorziening & Elektronica 1

Probleem Oorzaak Oplossing
Display is blank Batteries not installed or depleted Check that fresh AA alkaline batteries are installed as marked on the thermostat

Temperatuurproblemen 5

Probleem Oorzaak Oplossing
Temperature settings do not change Settings outside valid range Check that the temperature settings are: Heating 40°F to 90°F (4.5°C to 32°C), Cooling 50°F to 99°F (10°C to 37°C)
Heating system does not turn on Multiple possible causes including system mode, settings, power issues, or circuit breaker Set the system to Heat by pressing the System button. Check the heat temperature setting is above room temperature and 'Heat On' shows solidly. Verify circuit breaker is not tripped. Check power switch at heating system is on. Check furnace door is closed securely. Wait five minutes for system to respond. If issue persists, contact local heating and cooling contractor
Cooling system does not turn on Multiple possible causes including system mode, settings, power issues, or circuit breaker Set the system to Cool by pressing the System button. Check the cool temperature setting is below room temperature and 'Cool On' shows solidly. Verify circuit breaker is not tripped. Check power switch at cooling system is on. Check furnace door is closed securely. Wait five minutes for system to respond. If issue persists, contact local heating and cooling contractor
'Heat On' is not shown in the display System mode or temperature setting incorrect Set the System setting to Heat and set the temperature setting above the room temperature. If 'Heat On' is shown solidly but heating system does not turn on, see 'Heating system does not turn on' troubleshooting
'Cool On' is not shown in the display System mode or temperature setting incorrect Set the System setting to Cool and set the temperature setting below the room temperature. If 'Cool On' is shown solidly but cooling system does not turn on, see 'Cooling system does not turn on' troubleshooting

Community-vragen

Stel een vraag

Was ist 4 + 7?
De foutcodes zijn afkomstig uit de officiële handleiding van de fabrikant.

Andere Honeywell producten

Foutcode-assistent Online