Honeywell RTH6350
Thermostaat · 17 Probleemoplossingen
Probleemoplossing - Honeywell RTH6350
Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.
Overige problemen 8
| Probleem | Oorzaak | Oplossing |
|---|---|---|
Compressor 1
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| "Cool On" or "Heat On" flashes | Compressor safety function is active | Wait 5 minutes for the system to safely restart without compressor damage |
Fan 1
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Fan does not work when heating is needed | Function 3: Heating fan control not correctly set | Check Function 3: Heating fan control to ensure it matches your heating equipment (see page 16) |
Installatie & Opstelling 3
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Cannot change system setting to Cool | Function 1: System type not correctly set | Check Function 1: System type to ensure it matches your heating and cooling equipment (see page 14) |
| Heating and cooling equipment operate simultaneously or heating does not turn off | Bare wires touching or Function 1 not correctly set | Check Function 1: System type. Remove thermostat from wall panel and check that bare wires are not touching (see page 6) |
| Heating system operates in cooling mode | Function 1: System type not correctly set | Check Function 1: System type to ensure it matches your heating and cooling equipment (see page 14) |
Stroomvoorziening & Elektronica 1
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Display is blank | Empty or incorrectly placed batteries | Ensure fresh AA alkaline batteries are correctly installed (see page 7) |
Temperatuurproblemen 3
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Temperature settings do not change | Heating and cooling temperatures set outside acceptable ranges | Ensure heating and cooling temperatures are within acceptable ranges: Heat: 40°-90°F (4.5°-32°C). Cool: 50°-99°F (10°-37°C) |
| Heating or cooling system does not respond | System setting error, circuit breaker tripped, main switch off, or furnace door open | Set system to correct mode (Heat or Cool). Check that temperature is correctly set. Check circuit breaker. Ensure furnace door is closed. Wait 5 minutes for system response |
| Heat pump delivers cold air in heating mode or warm air in cooling mode | Function 2: Heat Pump Changeover Valve not correctly configured | Check Function 2: Heat Pump Changeover Valve to ensure it is correctly configured for your system (see page 15) |
Community-vragen
Stel een vraag
De foutcodes zijn afkomstig uit de officiële handleiding van de fabrikant.