Gorenje OTG120SLSIMC6
Ketel & boiler · 13 Probleemoplossingen
Probleemoplossing - Gorenje OTG120SLSIMC6
Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.
Overige problemen 8
| Probleem | Oorzaak | Oplossing |
|---|---|---|
Onderhoud & Verzorging 2
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Lime scale buildup inside heater | Water minerals accumulate on internal surfaces depending on water quality, quantity and temperature used | Authorized service specialist should perform inspection approximately every 2 years and clean lime deposits as needed |
| Low hot water output | Magnesium anode severely worn or fully consumed | Have authorized service specialist inspect and replace anode if diameter has significantly reduced or core is exposed |
Waterproblemen 3
| Probleem | Oorzaak | Oplossing |
|---|---|---|
| Water leaking from safety valve outlet | Water pressure increases when heating in closed system, causing water to drip from safety valve discharge hole | Direct discharge water to drain using special outlet fitting installed below safety valve, or install 3L expansion tank on water heater inlet pipe |
| Water freezing in heater during long non-use periods | Heater disconnected from power supply without draining water | Either leave heater connected to power with thermostat in '*' position to maintain ~10°C, or drain water by disconnecting blue inlet tube from water supply |
| Heater not filling with water properly | Air trapped in system during initial filling | At first filling, turn hot water handle on mixer tap; heater is full when water flows from mixer outlet pipe |
Community-vragen
Stel een vraag