Probleemoplossing - Gorenje GT5O

Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.

15 van 15

Overige problemen 10

Probleem Oorzaak Oplossing

Onderhoud & Verzorging 1

Probleem Oorzaak Oplossing
Excessive limescale buildup affecting performance Hard water deposits accumulate on internal surfaces depending on water quality, quantity, and temperature used Have an authorized service center perform regular maintenance every 36 months maximum to remove limescale and inspect the protective anode

Temperatuurproblemen 2

Probleem Oorzaak Oplossing
Risk of freezing when boiler is disconnected from power When the boiler is not connected to electricity and temperatures are cold, water inside can freeze Drain all water from the boiler if it will be disconnected from power for extended periods during freezing weather
Water not heating properly Thermostat setting may be too low or safety valve may be blocked with limescale Check and adjust thermostat setting; regularly test safety valve by opening the outlet to ensure water flows through and valve is not blocked

Waterproblemen 2

Probleem Oorzaak Oplossing
Water dripping from safety valve outlet Water pressure increases when heating in a closed pressure system, causing the safety valve to release pressure Install an expansion tank for sanitary water with a volume of at least 5% of the boiler capacity on the supply line to prevent dripping
Boiler not filling with water Water inlet may be closed or check valve may be stuck Ensure water supply is turned on; open hot water tap on mixer to allow tank to fill until water flows from mixer outlet