Probleemoplossing - Ariston Thermo Velis 80

Veelvoorkomende problemen en oplossingen - ook zonder foutcode op het display.

26 van 26

Overige problemen 10

Probleem Oorzaak Oplossing

Installatie & Opstelling 2

Probleem Oorzaak Oplossing
Poor water quality damages mixing groups Impurities in the pipes If you install mixing groups (faucets or shower mixer), you must flush any impurities from the pipes as they can damage these groups.
Display toont verkeerde oriëntatie Toestel is horizontaal geïnstalleerd Configureer de correcte weergave van het display door de toets 'mode' en de toets 'eco' gedurende 5 seconden tegelijk ingedrukt te houden.

Onderhoud & Verzorging 8

Probleem Oorzaak Oplossing
Reduced efficiency due to limescale buildup Limescale buildup on the heating elements (especially with hard water) Descale the heating elements (R fig. 6) approximately every two years. If you do not wish to use special descaling solutions, you can remove the buildup by crumbling the limescale crust. Be careful not to damage the heating element shield. With very hard water, increase this frequency.
Damaged anode reduces corrosion resistance Normal wear of the magnesium anode or aggressive water with high chlorine content Replace the magnesium anodes (N fig. 6) every two years (except for products with stainless steel tank). With aggressive water or high chlorine content, inspect the anode condition annually. To replace them, disassemble the heating elements and unscrew them from the support bracket.
Bypass line clogged Blockage in the bypass line The bypass line (X fig. 7) should only be inspected in case of defect caused by blockage. To inspect, loosen the two ring nuts (W fig. 7).
Overpressure protection blocked or damaged Limescale buildup or damage to the safety valve Regularly check that the overpressure protection is not blocked or damaged. Replace it if necessary or remove limescale buildup. Operate the lever or knob regularly to verify correct functioning.
Beschadigde kunststof bevestigingsplaatjes van het bedieningspaneel Verkeerd verwijderen van de bevestigingsplaatjes Gebruik een platte schroevendraaier voorzichtig om de bevestigingsplaatjes (A afb. 4b) weg te wippen en van de pinnen los te maken. Duw tegelijk naar buiten toe (2 afb. 4b) om het bedieningspaneel uit zijn zitting te halen. Herhaal voorzichtig op beide bevestigingsplaatjes. Zorg ervoor dat u de plastic plaatjes niet beschadigt, anders kan het paneel niet correct worden geassembleerd.

Prestaties & Werking 1

Probleem Oorzaak Oplossing
Device malfunction Possibly not related to the device itself: temporary water shortage or power outage Before requesting technical service intervention due to suspected defect, you must check whether the malfunction is not caused by other reasons, such as a temporary water shortage or a power outage.

Waterproblemen 5

Probleem Oorzaak Oplossing
Water leakage from connections Insufficient tightening torque on bolts or ring nuts Visually check for water leaking from the connections and bypass line. Slightly increase the tightening torque on the bolts (C fig. 5) and/or the ring nuts (W fig. 7).
Dripping from overpressure protection Normal phenomenon during water heating This is normal and not a malfunction. Ensure the drain outlet is connected with a drainage pipe that continuously slopes downward and is frost-free.
Water not completely drained from device Insufficient opening of the drainage valve To empty the device: ensure the device is permanently disconnected from the power supply, close the shutoff valve (or turn the main valve off), open the hot water faucet, and then open the drain valve (B fig. 1).
Air in water pipes Device was not completely filled with water Fill the device by opening the main valve of the home installation, as well as the hot water faucet, until all air has been released from the tank.
Water met ongeschikte hardheid Waterhardheid lager dan 12°F of hoger dan 25°F Het toestel mag niet werken met water waarvan de hardheid lager is dan 12°F, of met water met zeer grote waterhardheid (meer dan 25°F). In het laatste geval is het aanbevolen om een waterverzachter toe te passen die correct gekalibreerd en gecontroleerd is, zodat de resterende waterhardheid onder 15°F daalt.