Foutcodes - VänEE V180E75RT

Deze codes worden op het display van uw apparaat weergegeven wanneer er een probleem wordt gedetecteerd.

Meest voorkomende foutcodes - VänEE V180E75RT

C1
Group C1, residential occupancies, Group D2, business and pe...
E01
E01 Supply damper range STEP 1: Unplug unit, inspect the dam...
E02
E02 Supply damper timeout damper system). Plug unit.
E03
E03 Supply damper If STEP 1 did not x the problem, perform S...
E05
E05 Exhaust damper range STEP 1: Unplug the unit, inspect th...
33 van 33
Foutcode Beschrijving Oplossing Ernst
C1 Group C1, residential occupancies, Group D2, business and personal services occupancies, -
E01 E01 Supply damper range STEP 1: Unplug unit, inspect the damper system, remove any undesirable obstacle or dirt (lters and core may have to be removed to access the -
E02 E02 Supply damper timeout damper system). Plug unit. -
E03 E03 Supply damper If STEP 1 did not x the problem, perform STEP 2: Open electrical compartment, check if connector J5 (white) is well inserted, check for any -
E05 E05 Exhaust damper range STEP 1: Unplug the unit, inspect the damper system, remove any undesirable obstacle or dirt (lters and core may have to be removed to access the -
E06 E06 Exhaust damper timeout damper system). Plug the unit. If STEP 1 did not x the problem, perform STEP 2: Open electrical -
E07 E07 Uitlaatdemper compartiment, controleer of connector J7 (rood) correct is ingestoken, controleer op eventuele beschadigingen. -
E09 E09 Recirculatiedemper bereik STAP 1: Schakel het apparaat uit, inspecteer het dempersysteem, verwijder eventuele ongewenste obstakels of vuil (filters en kern kunnen moeten worden verwijderd voor toegang). -
E10 E10 Recirculation damper timeout damper system). Plug the unit. If STEP 1 did not x the problem, perform STEP 2: Open electrical -
E11 E11 Recirculation damper compartment, check if connector J6 (blue) is well inserted, check for any -
E22 E22 Supply airow STEP 1: Unplug the unit. Perform a visual inspection of the supply damper system. Clean lters, distribution registers and outside supply hood. Inspect -
E23 E23 Supply motor (drive over current) STEP 1: Unplug/plug unit. If STEP 1 did not x the problem, perform STEP 2: Remove core and clear -
E24 E24 Supply motor (drive over voltage) STEP 1: Unplug/plug unit. Under and over voltage may be detected with severe in-house power supply uctuation and stop the motor for protection. -
E25 E25 Supply motor (drive under voltage) If STEP 1 did not x the problem, perform STEP 2: Replace the electronic assembly. -
E26 E26 Supply motor (drive over temp) STEP 1: Validate if the air exchanger is exposed to ambient temperatures within the operating limits (see p. 4) -
E27 E27 Supply motor (drive foc duration) the ventilation wheel from any dirt or obstacles. If STEP 2 did not x the problem, perform STEP 3: Disconnect J2 (white) and -
E28 E28 Supply motor (drive speed feedback) connect a spare blower system. If it works, replace supply blower. -
E29 E29 Supply motor (startup) assembly. -
E32 E32 Exhaust airow STEP 1: Unplug the unit. Perform a visual inspection of the exhaust damper system. Clean lters, distribution registers and outside exhaust hood. Make -
E33 E33 Exhaust motor (drive over current) STEP 1: Unplug/plug unit. If STEP 1 did not x the problem, perform STEP 2: Remove core and clear the -
E34 E34 Exhaust motor (drive over voltage) STEP 1: Unplug/plug unit. Under and over voltage may be detected with severe in-house power supply uctuation and stop the motor for protection. -
E35 E35 Exhaust motor (drive under voltage) If STEP 1 did not x the problem, perform STEP 2: Replace the electronic assembly. -
E36 E36 Exhaust motor (drive over temp) STEP 1: Validate if the air exchanger is exposed to ambiant temperatures within the operating limits (see p. 4) -
E37 E37 Exhaust motor (drive foc duration) ventilation wheel from any dirt or obstacles. -
E38 E38 Exhaust motor (drive speed connect a spare blower system. If it works, replace exhaust blower. -
E39 E39 Exhaust motor (startup) assembly. E34 Exhaust motor (drive over voltage) STEP 1: Unplug/plug unit. Under and over voltage may be detected with -
E40 E40 Outside air thermistor STEP 1: Check if thermistor is well connected in connector J7A. If STEP 1 did not x the problem, perform STEP 2: Disconnect connector J7A -
E41 E41 Distribution air thermistor STEP 1: Check if thermistor is well connected in connector J7B. If STEP 1 did not x the problem, perform STEP 2: Disconnect connector J7B -
E42 E42 PCBA thermistor fault STEP 1: Replace the electronic assembly. E43 PCBA temperature over limit STEP 1: Validate if the air exchanger is exposed to ambiant temperatures -
E43 E43 PCBA temperature over limit STEP 1: Validate if the air exchanger is exposed to ambiant temperatures within the operating limits (see p. 4) -
E50 E50 Wall control communication lost STEP 1: Unplug unit, inspect wires, plug unit. If STEP 1 did not x the problem, perform STEP 2: Remove wall control from -
E51 E51 Wall control sensor STEP 1: Unplug unit, inspect wires, plug unit. If STEP 1 did not x the problem, perform STEP 2: Replace the wall control. -
E60 E60 Beveiligingsmodus STAP 1: Voer algemene inspectie van het apparaat uit (dempersysteem, kern, filters). -

Community-vragen

Stel een vraag

Was ist 5 + 3?
De foutcodes zijn afkomstig uit de officiële handleiding van de fabrikant.

Andere VänEE producten

Foutcode-assistent Online
Hallo! Ik ben uw foutcode-assistent voor de VänEE V180E75RT. Voer een foutcode in en ik leg u uit wat het betekent en hoe u het probleem kunt oplossen.